Tono-Pachy Meter M-TONX

The M-TONX H1 multi function device, which has obtained national and international patents, is the result  of a  5-year  team work of the relevant experts and the cooperation of the two universities of  Linköping Sweden and the University of Medical Sciences of Iran, and is managed and implemented by Moj Teb   Parsian. This product has a  manufacturing license from the Food and Drug Organization and conforms to the ISO13485-2016 standard

T1 tonometer

The M-TONX H1 tonometer device uses Vandad Technology, which is a combination of boundd and rebound technique, which measures two intertwined but independent parameters of intraocular pressure and corneal thickness simultaneously and with one sensor. Most of the similar measuring devices have systematic errors due to. the measurement of intraocular pressure on the cornea, in such a way that the cornea is thinner or thicker than the reference value (10 +- 530) microns, causing under and over estimating

Moj Teb Parsian

Specifications

It is necessary to remember that most intraocular pressure measuring devices have systematic errors due to intraocular pressure measurement from the cornea, so that the cornea is thinner or thicker than the reference value (10+-530). Microns cause under-estimation and over-estimation, respectively

Gentel touch withouthou pain

Perpendicular Position Indicator

No Need for Daily Calibration

High Accurracy

The basis of measurement in this device is based on the advanced and intelligent processing of the speed curve of the probe movement, which is the basis of the measurement in two sections, IOP and CCT

In the IOP section, the acceleration of the probe stopping on the eye along with other considerations are processed on the velocity-time curve

In the CCT section, the kinetic energy losses of the probe along with the acceleration of the probe stop and several parameters are processed on the speed-time curve

It should be noted that many parameters are effective in measuring intraocular pressure and corneal thickness in this system, the description of which is beyond the scope of this section, and only here the scientific principles of measurement in each section are mentioned

Why M-Tonx

Z

M-Tonx

Suitable for kids,children and adults

Z

M-Tonx

Suitable for early diagnosis of patients with glaucoma and keratoconus

Z

M-Tonx

No need for periodic service and repairs

Let’s Start Now

Make sure to subscribe to our newsletter to receive our latest news and special offers.